Himfloor FC 450 P/FC 450 R

HIM

Epoxy resin floor coating with a very high dry solid contents

Uses

Himfloor FC450 R or P can be used indoors, because of the very lo solvent contents .Himfloor FC450 R or P provides a thin, coloured floor finish, with is specifically recommended for surfaces with foot traffic, light transport and forklift trucks.

Advantages

  • Durable-good resistance to abrasion
  • Non-porous surface
  • Good adhesion
  • Easy to apply and to maintain
  • Very low solvent contents,which allows the product to be applied indoors

Maintenance

The service life a floor can be considerably extended by good housekeeping .Regular cleaning may be carried out using a rotary scrubbing machine with a water miscible cleaning agent at temperatures up to 50°C. During the first 7 days the floor should not be cleaned with a water based cleaning agent.

Product description

Himfloor FC450 is a floor coating, based on epoxy, with a very high dry solid contents. There are two versions of Himfloor FC450.
The R-version is specially developed to seal sanded surfaces. It has excellent de-airing properties. The P-version is a rollable coating. The product can be used to seal the pores of epoxy mortars.
Himfloor FC450 R or P is supplied in 2 components after curing the product forms a durable coat, which has a good adhesion to all well prepared wooden, iron and concrete substrates.

Colours

Himfloor FC450 can be supplied in a wide range of RAL-colours. See the Himfloor colour chart.

Flooring system

As a paint:2 coats of Himfloor FC450 P
As a sealcoat : Himfloor FC450 R is used to seal the sanded substrate with a steel trowel or a rubber float .

Technical data

Mixing ratio Parts by weight base : hardener
20.6 :4,4(R-version)
20.6 :4,6(P-version)
Mixing ratio Parts by volume base : hardener
approx. 12,9: 4,4 (R-version)
approx.12,9 :4,6 (P-version)
Specific gravity (mixed) approx. 1,5
Volume solids (mixed) 96,5-98 % w/w (depending on version)
94,0-97 % v/v (depending on version
Temperatures resistance Up to 70 °C in air
Material consumption (thero.) R-version 0,5 kg/m² (depending on substrate)
P-version 0,3 kg/m² (depending on substrate)
Poltif at 20°C 30 minutes
Curing time at 20°C Foot traffic after 24 hours, vehicular traffic after 48 hours, fully cured after 7 days

Temperature limitations

Himfloor FC450 should not be applied at temperatures below 10°C, nor at a substrate temperature which is lower than the dew point temperature plus 3°C. The maximum application temperature is 35°C .The maximum relative humidity is 80%

Surface preparation

It is essential to thoroughly prepare the floor surface in order to achieve a Sound, clean and dry substrate, preferably by blasting. Substrates, contaminated by oil or grease, should be cleaned with suitable cleaning agents, followed by cleaning with lots of water. Allow the floor to dry for at least 48 hours.

Limitations

New cement based floors should be at least 28 days old and give a hygrometer reading not exceeding 5% (Protimeter).Vapour pressure may result in de-bonding of the finishing coat. It is essential to carry out the “rubber mat” test.Craks or movement in the substrate, may re-appear in the finish coat. Existing dilations should be repeated in the finish coat.

Primer

If required, a primer may be used, provided Himfloor FC450 R or P is applied within 24 hours.

Mixing

The pigmented base component (A) of Himfloor FC450 should be thoroughly homogenised before mixing it with the hardener component (B) .Mix further for at least 3 minutes .
The use of a heavy duty slow speed drill fitted with a mixing paddle is desirable.

Application

The mixed Himfloor FC450 should be applied to the prepared surface in 2 coats, using a roller, ensuring that the rolling takes place in straight lines and cross-wise. The second coat may be applied as soon as one can walk on the floor, but within 24 hours .The waiting time depends on the condition of substrate and surroundings. If the second coat is applied after more than 24 hours, the substrate should be prepared again.

Disposal

Disposal of spillage or empty packaging should be in accordance with local waste disposal regulation .
For futher information refer to the Material Safety Data Sheet.

Material consumption (theor.)

Himfloor FC450 R: 0,5 kg/m²
Himfloor FC450 P: 0, 3 kg/m²
These figures are based on a smooth substrate and a temperature of 20°C.

Potlife at 20°C

30 minutes.

Curing time at 20°C

Foot traffic after 24 hours, vehicular traffic after 48 hours, fully cured after 7 days

Tool cleaning

Himfloor FC450 R or P can be removed from tools and equipment with HIM Solvent 102.The cured product can only be removed mechanically.

Shelflife

Himfloor FC450 R or P has a shelf life of 12 months if kept in a dry store in the original, unopened packs. Minimum storage temperature is 5°C .Ideal storage temperature is between 15°C and 25°C

Safety precautions

Avoid contact with skin and eyes. Use only in well ventilated areas. In case of insufficient ventilation, wear suitable respiratory equipment. Do not breath vapour. Wear suitable protective clothing, gloves and eye/face protection. If swallowed, seek medical advice immediately and show the container or label-do not induce vomiting. After contact with skin, wash immediately with plenty of water and soap .In case of contact eyes, rinse immediately with plenty of water and seek of ignition-do not smoke. For further information, refer to the Material Safety Data sheet.

Flash points

Himfloor FC450 Base > 100°C
Himfloor FC450 R hardener 84°C
Himfloor FC450 R hardener 68°C
HIM Solvent 102 32°C
HIM Industrial and
decorative flooring
protective
coatings
for steel and concrete
   
 
  HIM Netherlands
Wijkermeerweg 12
PO box 1
1950 AA Velsen-Noord
téléphone +31(0)251-276 300
télécopie +31 251 225 031
HIM France
50 avenue des Frères Lumière
ZA Trappes-Elancourt BP135
78996 trappes cedex
telephone +33 (0)1 30069 3782
fax +33(0)1 3069 3793
Him Belgium
Leenstraat 42
9070 Heusden (O-VL)
telephone +32(0)99 232 1111
télécopie +32(0) 9 230 6906
DNV company
certified
ISO 9001

Important notice

notice the above data are based on tests believed to be reliable and are given for information only. The data are correct on the issuing date sheet. Since conditions of use are beyond our control, we cannot and do not assume any liability in connection with the use of product relative to coverage performance. Injury or any other achievement. Published data are subject to be modified without prior notice. We therefore advice you to inquire approx. 12 months after issuing date of this data sheet if all data are still valid and up-to-date.